Filter Bag Solenoid Valve

Pulse valve is composed of pilot head, diaphragm and valve aluminum body. The back cavity area of diaphragm is bigger than the front one. The diaphragm is kept at the closed position due to the effect of big pressure.

Product Details

1.Introduction

Pulse valve is composed of pilot head, diaphragm and valve aluminum body. The back cavity area of diaphragm is bigger than the front one. The diaphragm is kept at the closed position due to the effect of big pressure.

Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.

The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.

The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning..

Filter bag solenoid valve

2.Specification

Operation mode

Normal close

Electricity open, deenergize close

Medium Temp.

≤ 60 °C

Medium

Air

Nominal diameter. (mm)

15

20

25

32

40

50

65

80

100

Connection Size. (G)

1/2

3/4

1

1-1/4

1-1/2

2

2-1/2

3

4

Pressure (Mpa)

0.03-0.8

Service life

Jetting more than 1.5 million times

Voltage deviation

Allowed fluctuate ±10%

Material

Valve

Precision casting of aluminium alloy

Seal

Nitrile buna rubber (NBR)

Environment Temp.

-20-60 °C

Connection type

Internal thread

Electrical connection

Socket of terminal box cable, IP Grade IP65

Voltage

AC 220 V  50Hz/60Hz, DC: 24 V, other according requirement

Special selection

BZCJ Anti-explosion Electromagnetic Valve

Anti-explosion grade: Exml/llT4 (Encapsulated), dllBT4,dllCT5 (with hydrogen)

Installation

Priority in using vertical coil, also can according to requirement

Note

The valve fully open or closed, need at least 0.1Mpa pressure difference

Application

3.Packing and shipping

Packing and shipping

about tr